{"id":72339,"date":"2024-03-27T10:50:25","date_gmt":"2024-03-27T14:50:25","guid":{"rendered":"https:\/\/www.mdaturbines.com\/?p=72339"},"modified":"2024-03-27T10:50:25","modified_gmt":"2024-03-27T14:50:25","slug":"7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind","status":"publish","type":"post","link":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/","title":{"rendered":"7FH2 Partial Re-Stack of the Core Step Iron &#038; Full Stator Rewind"},"content":{"rendered":"<p>Mechanical Dynamics &amp; Analysis performed a 7FH2 Partial Re-Stack of the core step iron &amp; Full Stator Rewind on a GE\u00ae 7FH2 generator.<\/p>\n<p>Several 7FH2 units have experienced failures of the core step iron, caused by inadequate compression of the core laminations.\u00a0 This issue was first brought to light by GE\u00ae TIL 2260, which only covered certain units; however, this recent failure was outside the scope of this TIL, indicating that other units may be at risk of a similar failure.<\/p>\n<p>MD&amp;A recommends that all 7FH2 generators be subjected to core tightening, preferably during the rewind of the stator.\u00a0 However, if no rewind is in scope, then the core tightening should be performed during the next planned outage. Many of the 7FH2 units are more than 25 years old and are approaching their intended design life.\u00a0 This particular unit had the damaged core iron replaced and windings replaced.<\/p>\n<table style=\"height: 525px;\" width=\"724\">\n<tbody>\n<tr>\n<td width=\"208\"><img decoding=\"async\" class=\"aligncenter wp-image-72344 size-medium\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1-225x300.jpg\" alt=\"7FH2 Partial Re-Stack of the Core Step Iron\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1-225x300.jpg 225w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1-120x160.jpg 120w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1-68x90.jpg 68w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1.jpg 333w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/td>\n<td style=\"text-align: center;\" width=\"194\">\u00a0<img decoding=\"async\" class=\"alignnone size-medium wp-image-72341\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture2-225x300.jpg\" alt=\"\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture2-225x300.jpg 225w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture2-120x160.jpg 120w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture2-68x90.jpg 68w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture2.jpg 351w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"402\"><img decoding=\"async\" class=\"size-medium wp-image-72343 aligncenter\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture3-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture3-300x225.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture3-213x160.jpg 213w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture3-90x68.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture3.jpg 468w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The unit was last inspected during spring 2020 utilizing a <a href=\"https:\/\/www.mdaturbines.com\/services\/generator\/robotic-generator-in-situ-inspection\/\">generator robot<\/a> and was classified as \u201cgood\u201d with no issues noted, indicating that the issue can develop &amp; present over a short period of time.<\/p>\n<p>The outage started as a <a href=\"https:\/\/www.mdaturbines.com\/services\/gas-turbine\/turnkey-inspections\/\">Gas Turbine Hot Gas Path<\/a> with Generator Robotic In-Situ Inspection. The Generator scope included a full battery of <a href=\"https:\/\/www.mdaturbines.com\/services\/generator\/generator-testing-inspections\/\">electrical testing<\/a> on the field &amp; stator. The <a href=\"https:\/\/www.mdaturbines.com\/services\/generator\/robotic-generator-in-situ-inspection\/\">Robotic In-Situ Visual Inspection<\/a> included a Wedge Map, &amp; ELCID core iron assessment.<\/p>\n<p>The Robot crawler traversed axially from CE (collector end) to TE (turbine end) utilizing both a straight facing camera and 360-degree rotating camera to assess wedges, core iron condition, field body, and to note any abnormalities. The initial inspection proved highly challenging due to the amount of oil\/greasing present on the stator, particularly on TE \u2013 as the robot began slipping. At the 12 o\u2019clock position, MD&amp;A noted high amounts of contamination at TE step iron and body wedge system.<\/p>\n<p>After discussing recommendations and repair options, the Customer opted for a partial re-stack of the core step iron and full stator rewind. Three full packs of iron and full set of 7FH2 windings were readily available as part of MD&amp;A\u2019s inventory. The <a href=\"https:\/\/www.mdaturbines.com\/repairs\/generator\/field-services\/\">generator field<\/a> was shipped to MD&amp;A\u2019s Turbine-Generator Repair Facility where thorough <a href=\"https:\/\/www.mdaturbines.com\/services\/generator\/generator-testing-inspections\/\">inspection and testing<\/a> of the field was performed. This allowed the field to be in a controlled climate to reduce the potential for moisture ingress during the stator repair activity duration.<\/p>\n<p>The repair of this unit required that the generator be stripped of all stator windings, followed by a thorough cleaning of the stator to remove all core ferrous debris from the stator prior to performing <a href=\"https:\/\/www.mdaturbines.com\/repairs\/generator\/stator-repair\/\">the rewind.<\/a><\/p>\n<p>The damaged iron was removed from the stator core in circumferential sections moving axially inboard from the TE step iron where the fretted iron was located. Core iron packs were removed just past the damaged section to ensure reliability for future operation of the unit.<\/p>\n<p>Once the core iron was removed, new core iron was replaced in the reverse process, moving axially outboard in circumferential bands. With the new core iron in place, MD&amp;A then axially compressed the core to the required values. A Core Loop test was performed at the completion of the <a href=\"https:\/\/www.mdaturbines.com\/repairs\/generator\/stator-repair\/\">partial re-stack<\/a> to verify successful compression of the new core and to ensure no hotspots were present on the newly installed or original remaining core iron.<\/p>\n<p>&nbsp;<\/p>\n<table style=\"height: 416px;\" width=\"747\">\n<tbody>\n<tr>\n<td width=\"183\"><img decoding=\"async\" class=\"alignnone size-medium wp-image-72342 aligncenter\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630-300x200.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630-1024x683.jpg 1024w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630-768x512.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630-1536x1024.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630-240x160.jpg 240w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630-90x60.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09630.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<td style=\"text-align: center;\" width=\"182\">\u00a0 \u00a0<img decoding=\"async\" class=\"alignnone wp-image-72345 size-medium\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716-300x200.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716-1024x683.jpg 1024w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716-768x512.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716-1536x1024.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716-240x160.jpg 240w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716-90x60.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSC09716.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"366\"><img decoding=\"async\" class=\"size-medium wp-image-72346 aligncenter\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235-300x200.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235-1024x683.jpg 1024w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235-768x512.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235-1536x1024.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235-240x160.jpg 240w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235-90x60.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/DSCF6235.jpg 2048w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>After the core iron was replaced, new 7FH2 generator stator windings were installed. All quality checks were performed according to MD&amp;A procedures to ensure reliable future operation of the unit.<\/p>\n<p><strong>Stator Experts<\/strong><\/p>\n<p>MD&amp;A has a long track record of successful generator stator inspections and rewinds on-site. You can count on MD&amp;A\u2019s attention to quality!<\/p>\n<p>Additionally MD&amp;A has <a href=\"https:\/\/www.mdaturbines.com\/parts\/spare-assets\/#%3Cstrong%3EGenerator%20Fields:%3C\/strong%3E\">Stator Rewind Kits<\/a> available for immediate use along with new step iron laminations in stock for 7FH2 units. There are several options of on the shelf rewind kits including GE\u00ae 7FH2, 7A6, 9A4 and 324 units.<\/p>\n<p>For any questions or concerns about operational issues with these large generators, or to arrange service or inspection, contact MD&amp;A\u2019s generator experts today at +1 (314) 880-3000 or use our <a href=\"https:\/\/www.mdaturbines.com\/contact\/\">Contact Form<\/a>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-72340 size-medium\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture-loop-300x225.jpg\" alt=\"7FH2 Partial Re-Stack of the Core Step Iron\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture-loop-300x225.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture-loop-213x160.jpg 213w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture-loop-90x68.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture-loop.jpg 472w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mechanical Dynamics &amp; Analysis performed a 7FH2 Partial Re-Stack of the core step iron &amp; Full Stator Rewind on a GE\u00ae 7FH2 generator. Several 7FH2&#8230;<\/p>\n","protected":false},"author":13,"featured_media":72344,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[210,3],"tags":[78,305,226,121],"class_list":["post-72339","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-generator","category-mda-insight","tag-7fh2","tag-core-step-iron","tag-generator","tag-stator-rewind"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>7FH2 Partial Re-Stack of the Core Step Iron &amp; Full Stator Rewind &#8211; MDA Turbines<\/title>\n<meta name=\"description\" content=\"MD&amp;A has performed a GE\u00ae 7FH2 Partial Re-Stack of the core step iron &amp; Full Stator Rewind for a customer. Read the success story.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"7FH2 Partial Re-Stack of the Core Step Iron &amp; Full Stator Rewind &#8211; MDA Turbines\" \/>\n<meta property=\"og:description\" content=\"MD&amp;A has performed a GE\u00ae 7FH2 Partial Re-Stack of the core step iron &amp; Full Stator Rewind for a customer. Read the success story.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/\" \/>\n<meta property=\"og:site_name\" content=\"MDA Turbines\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/mdaturbines\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-27T14:50:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"333\" \/>\n\t<meta property=\"og:image:height\" content=\"444\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Caitlin Borger\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Caitlin Borger\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/\"},\"author\":{\"name\":\"Caitlin Borger\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/person\\\/fdbd01ed3b81195a72d31a7c9d59d29e\"},\"headline\":\"7FH2 Partial Re-Stack of the Core Step Iron &#038; Full Stator Rewind\",\"datePublished\":\"2024-03-27T14:50:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/\"},\"wordCount\":703,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/Picture1.jpg\",\"keywords\":[\"7FH2\",\"Core Step Iron\",\"Generator\",\"stator rewind\"],\"articleSection\":[\"Generator\",\"MD&amp;A Insight\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/\",\"name\":\"7FH2 Partial Re-Stack of the Core Step Iron & Full Stator Rewind &#8211; MDA Turbines\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/Picture1.jpg\",\"datePublished\":\"2024-03-27T14:50:25+00:00\",\"description\":\"MD&A has performed a GE\u00ae 7FH2 Partial Re-Stack of the core step iron & Full Stator Rewind for a customer. Read the success story.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/Picture1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/Picture1.jpg\",\"width\":333,\"height\":444},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.mdaturbines.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"7FH2 Partial Re-Stack of the Core Step Iron &#038; Full Stator Rewind\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"name\":\"MD&A Turbines\",\"description\":\"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\"},\"alternateName\":\"Mechanical Dynamics & Analysis\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.mdaturbines.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\",\"name\":\"Mechanical Dynamics & Analysis\",\"alternateName\":\"MD&A Turbines\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"width\":1179,\"height\":258,\"caption\":\"Mechanical Dynamics & Analysis\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/mdaturbines\",\"https:\\\/\\\/x.com\\\/mdaturbines\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/person\\\/fdbd01ed3b81195a72d31a7c9d59d29e\",\"name\":\"Caitlin Borger\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g\",\"caption\":\"Caitlin Borger\"},\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/author\\\/caitlin-borger\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"7FH2 Partial Re-Stack of the Core Step Iron & Full Stator Rewind &#8211; MDA Turbines","description":"MD&A has performed a GE\u00ae 7FH2 Partial Re-Stack of the core step iron & Full Stator Rewind for a customer. Read the success story.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/","og_locale":"en_US","og_type":"article","og_title":"7FH2 Partial Re-Stack of the Core Step Iron & Full Stator Rewind &#8211; MDA Turbines","og_description":"MD&A has performed a GE\u00ae 7FH2 Partial Re-Stack of the core step iron & Full Stator Rewind for a customer. Read the success story.","og_url":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/","og_site_name":"MDA Turbines","article_publisher":"http:\/\/www.facebook.com\/mdaturbines","article_published_time":"2024-03-27T14:50:25+00:00","og_image":[{"width":333,"height":444,"url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1.jpg","type":"image\/jpeg"}],"author":"Caitlin Borger","twitter_misc":{"Written by":"Caitlin Borger","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#article","isPartOf":{"@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/"},"author":{"name":"Caitlin Borger","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/person\/fdbd01ed3b81195a72d31a7c9d59d29e"},"headline":"7FH2 Partial Re-Stack of the Core Step Iron &#038; Full Stator Rewind","datePublished":"2024-03-27T14:50:25+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/"},"wordCount":703,"commentCount":0,"publisher":{"@id":"https:\/\/www.mdaturbines.com\/#organization"},"image":{"@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1.jpg","keywords":["7FH2","Core Step Iron","Generator","stator rewind"],"articleSection":["Generator","MD&amp;A Insight"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/","url":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/","name":"7FH2 Partial Re-Stack of the Core Step Iron & Full Stator Rewind &#8211; MDA Turbines","isPartOf":{"@id":"https:\/\/www.mdaturbines.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#primaryimage"},"image":{"@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1.jpg","datePublished":"2024-03-27T14:50:25+00:00","description":"MD&A has performed a GE\u00ae 7FH2 Partial Re-Stack of the core step iron & Full Stator Rewind for a customer. Read the success story.","breadcrumb":{"@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#primaryimage","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1.jpg","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/03\/Picture1.jpg","width":333,"height":444},{"@type":"BreadcrumbList","@id":"https:\/\/www.mdaturbines.com\/resources\/7fh2-partial-re-stack-of-the-core-step-iron-full-stator-rewind\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mdaturbines.com\/"},{"@type":"ListItem","position":2,"name":"7FH2 Partial Re-Stack of the Core Step Iron &#038; Full Stator Rewind"}]},{"@type":"WebSite","@id":"https:\/\/www.mdaturbines.com\/#website","url":"https:\/\/www.mdaturbines.com\/","name":"MD&A Turbines","description":"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..","publisher":{"@id":"https:\/\/www.mdaturbines.com\/#organization"},"alternateName":"Mechanical Dynamics & Analysis","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mdaturbines.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mdaturbines.com\/#organization","name":"Mechanical Dynamics & Analysis","alternateName":"MD&A Turbines","url":"https:\/\/www.mdaturbines.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","width":1179,"height":258,"caption":"Mechanical Dynamics & Analysis"},"image":{"@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/mdaturbines","https:\/\/x.com\/mdaturbines"]},{"@type":"Person","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/person\/fdbd01ed3b81195a72d31a7c9d59d29e","name":"Caitlin Borger","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g","caption":"Caitlin Borger"},"url":"https:\/\/www.mdaturbines.com\/resources\/author\/caitlin-borger\/"}]}},"_links":{"self":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/72339","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/comments?post=72339"}],"version-history":[{"count":9,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/72339\/revisions"}],"predecessor-version":[{"id":72362,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/72339\/revisions\/72362"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media\/72344"}],"wp:attachment":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media?parent=72339"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/categories?post=72339"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/tags?post=72339"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}