{"id":70258,"date":"2022-05-04T15:31:00","date_gmt":"2022-05-04T19:31:00","guid":{"rendered":"https:\/\/www.mdaturbines.com\/?p=70258"},"modified":"2022-05-04T15:31:00","modified_gmt":"2022-05-04T19:31:00","slug":"spare-lpb-rotor-and-diaphragm-repairs","status":"publish","type":"post","link":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/","title":{"rendered":"Spare LPB Rotor and Diaphragm Repairs"},"content":{"rendered":"<p>Steam turbine experts at Mechanical Dynamics &amp; Analysis (MD&amp;A) have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae G2 design unit. The site had removed the crossover and outer shell to find severe damage and missing blades in the turbine\u2019s low-pressure section. MD&amp;A was contracted to inspect the spare LPB (low-pressure B turbine) rotor and diaphragms and determine needed repairs.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-70447 size-large\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-1024x768.jpg\" alt=\"Spare LPB Rotor and Diaphragm Repairs\" width=\"1024\" height=\"768\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-1024x768.jpg 1024w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-300x225.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-768x576.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-1536x1152.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-2048x1536.jpg 2048w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-213x160.jpg 213w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_5503-90x68.jpg 90w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>In this unit, the HP-IP section contains 12 stages. LPA and LPB each have 7 stages per flow, stages 13 through 19.<\/p>\n<p>All LPB components were sent to MD&amp;A\u2019s Turbine-Generator Repair Facility in St. Louis, MO for immediate incoming inspection, analysis, and recommendations.<\/p>\n<p><u>Couplings and journals<\/u><\/p>\n<p>The rotor was blast-cleaned followed by visual, non-destructive examination, and dimensional assessments.<\/p>\n<p>Turbine-end and generator-end couplings had minor rust and pitting on the faces and outside diameters, and numerous coupling holes showed moderate galling. MD&amp;A would remove the galling to prepare for proper on-site reassembly. The generator end rabbet fit was peened and machined to maintain diameter and remove .002 in. runout when operating on both journals.<\/p>\n<p>The two journals, T5 and T6, had moderate surface rust, pitting, radial scoring, and between .002\u201d and .004\u201d taper. Both were <a href=\"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/field-machining\/\">machined<\/a> to remove the taper and damaged material, and oil seal lands were strap lapped.<\/p>\n<figure id=\"attachment_70446\" aria-describedby=\"caption-attachment-70446\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-medium wp-image-70446\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/Machined-Journal-300x225.jpg\" alt=\"Machined Journal\" width=\"300\" height=\"220\" \/><figcaption id=\"caption-attachment-70446\" class=\"wp-caption-text\">Machined Journal<\/figcaption><\/figure>\n<p><u>Buckets<\/u><\/p>\n<p>All rotor rotating stages had varying degrees of pitting and foreign-object damage on buckets and covers, including the outside of the roots and tenons. Magnetic particle NDE was performed on the rotor, liquid penetrant NDE was performed on the L-1 titanium notch buckets, and phased array ultrasonic NDE was performed on the L-0 finger dovetail pins. NDE reports confirmed corrosion pitting on all stages but revealed no crack-like indications. Moderate to severe erosion was noted on the L-1 tenons and L-0 buckets.<\/p>\n<p>Minor repairs were performed on stages 13 through 18. Leading and trailing edges were straightened and blended, and polishing removed foreign object damage.<\/p>\n<p>Six buckets with severe tenon erosion were replaced on the stage 18 turbine end (TE), including the titanium notch blade. Stage 18 (L-1) TE and generator-end (GE) tenons were high-velocity oxygen fuel coated with chromium carbide to slow the progress of erosion.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"312\">\n<p><figure id=\"attachment_70448\" aria-describedby=\"caption-attachment-70448\" style=\"width: 225px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-70448 size-medium\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-225x300.jpg\" alt=\"\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-225x300.jpg 225w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-768x1024.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-1152x1536.jpg 1152w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-1536x2048.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-120x160.jpg 120w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-68x90.jpg 68w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6043-scaled.jpg 1800w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><figcaption id=\"caption-attachment-70448\" class=\"wp-caption-text\">Before<\/figcaption><\/figure><\/td>\n<td style=\"text-align: center;\" width=\"312\">\n<p><figure id=\"attachment_70445\" aria-describedby=\"caption-attachment-70445\" style=\"width: 225px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"wp-image-70445 size-medium\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-225x300.jpg\" alt=\"\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-225x300.jpg 225w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-768x1024.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-1152x1536.jpg 1152w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-1536x2048.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-120x160.jpg 120w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-68x90.jpg 68w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6611-scaled.jpg 1800w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><figcaption id=\"caption-attachment-70445\" class=\"wp-caption-text\">After<\/figcaption><\/figure><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>At stage 19, the L-0 row, both the TE and GE buckets had heavy erosion on the discharge side of the leading edges. Due to the long lead time for bucket replacements, MD&amp;A experts recommended annual, in-hood inspection of erosion while procuring new buckets for replacement at the next major outage.<\/p>\n<p><u>Diaphragms<\/u><\/p>\n<p>NDE (MT and PT) was performed on the diaphragms. Common to all was moderate pitting on the partitions, setback faces, appendages, horizontal joints, and diaphragm body.<\/p>\n<p>Of highest concern was pitting on the partitions. This had created small holes near some trailing edges.<\/p>\n<p>Also noted was a large amount of missing hardware. Several lower half diaphragms did not have support blocks, and no joint bolts were present for stages 13 or 19.<\/p>\n<p>Stage 13, the first low-pressure stage, is a bolted assembly consisting of both the turbine-end and generator-end diaphragms. The heavily eroded appendage was weld repaired near the joint where damage was most severe. High spots from FOD were removed and trailing edges were hand-blended and straightened. Indications found on previous Inconel restorations were also repaired.<\/p>\n<p>The base material of the stage 14 partitions had moderate to severe pitting on both the concave and convex sides, which was repaired. High spots from FOD were removed and trailing edges were blended and straightened. Four new support blocks and new keys were provided.<\/p>\n<p>Stage 15 partitions had moderate erosion and pitting. Pitting near the thin trailing edges had created small holes. If not repaired, more holes would appear and pieces would liberate and move downstream. Major Stage 15 repairs, therefore, became critical. MD&amp;A specialists repaired the trailing edges by cutting back to a minimum thickness of 0.125 in. and welding new partitions in place, hand-working to match the incoming profiles. A damaged root radial seal was also repaired. Support blocks and various screws and keys were provided.<\/p>\n<p>Although not as severe, small holes were found near the trailing edges of stage 16, primarily near the corners. Stage 16 joint blades were more severely damaged. All affected areas were cut back and repaired with Inconel. The remaining blades were straightened.<\/p>\n<p>At stages 17 and 18, there was moderate damage to the joint blades, causing trailing edge deformation and small tears. These were weld-repaired, as was all FOD.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"312\">\n<p><figure id=\"attachment_70449\" aria-describedby=\"caption-attachment-70449\" style=\"width: 300px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"size-medium wp-image-70449\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/pg-57-300x207.jpg\" alt=\"\" width=\"300\" height=\"207\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/pg-57-300x207.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/pg-57-232x160.jpg 232w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/pg-57-90x62.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/pg-57.jpg 531w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-70449\" class=\"wp-caption-text\">Before<\/figcaption><\/figure><\/td>\n<td width=\"312\">\n<p><figure id=\"attachment_70444\" aria-describedby=\"caption-attachment-70444\" style=\"width: 279px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\" wp-image-70444\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-300x225.jpg\" alt=\"\" width=\"279\" height=\"209\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-300x225.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-1024x768.jpg 1024w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-768x576.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-1536x1152.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-2048x1536.jpg 2048w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-213x160.jpg 213w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/04\/IMG_6405-90x68.jpg 90w\" sizes=\"(max-width: 279px) 100vw, 279px\" \/><figcaption id=\"caption-attachment-70444\" class=\"wp-caption-text\">After<\/figcaption><\/figure><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>MD&amp;A straightened and weld-repaired damaged trailing edges and repaired all NDE indications at stage 19.<\/p>\n<p>All damaged packing retaining pin holes were weld-repaired and extra stock was welded to the crush pins to be fit on-site, to expedite reassembly. Broken diaphragm key screws were replaced, and new keys were made to replace those missing.<\/p>\n<p><u>Recommendations<\/u><\/p>\n<p>After all the repairs were completed, a <a href=\"https:\/\/www.mdaturbines.com\/repairs\/steam-turbine\/high-speed-balance\/\">high-speed balance<\/a> was performed on the LPB rotor. The rotor was cleaned and prepared for shipment.<\/p>\n<p>MD&amp;A analysts recommended that the site monitor any pitting on the rotor and diaphragms and any progression of tenon erosion. Major future repair to stage 14 diaphragms should be considered.<\/p>\n<p>For the stage 19 L-0 buckets, annual in-hood erosion inspections should be performed until near-term replacement.<\/p>\n<p>MD&amp;A completed both analysis and repair of this spare LPB unit on schedule and returned the unit ready for full service.<\/p>\n<p>MD&amp;A experts focused on detailed analysis and needed repair while leaving the owner\/operator with both near-term confidence and a long-term plan for reliable performance of this critical G2 design unit.<\/p>\n<p>Call MD&amp;A today for any turbine\/generator repair at +1 (314) 880-3000 or use our <a href=\"https:\/\/www.mdaturbines.com\/contact\/\">Contact form<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"312\"><img decoding=\"async\" class=\"alignnone wp-image-70259 size-medium\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-300x169.jpg\" alt=\"Spare LPB Rotor and Diaphragm Repairs\" width=\"300\" height=\"169\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-300x169.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-1024x576.jpg 1024w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-768x432.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-1536x864.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-2048x1152.jpg 2048w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-284x160.jpg 284w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-90x51.jpg 90w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<td width=\"312\"><img decoding=\"async\" class=\"alignnone wp-image-70260 size-medium\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-300x169.jpg\" alt=\"Spare LPB Rotor and Diaphragm Repairs\" width=\"300\" height=\"169\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-300x169.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-1024x576.jpg 1024w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-768x432.jpg 768w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-1536x864.jpg 1536w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-2048x1152.jpg 2048w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-284x160.jpg 284w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0033-90x51.jpg 90w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Steam turbine experts at Mechanical Dynamics &amp; Analysis (MD&amp;A) have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae G2 design unit&#8230;.<\/p>\n","protected":false},"author":13,"featured_media":70259,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[209],"tags":[77,268,267],"class_list":["post-70258","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-steam-turbine","tag-steam-turbine","tag-steam-turbine-parts","tag-steam-turbine-repairs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Spare LPB Rotor and Diaphragm Repairs &#8211; MD&amp;A Turbines<\/title>\n<meta name=\"description\" content=\"Steam turbine experts at MD&amp;A have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae Frame G2 unit.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Spare LPB Rotor and Diaphragm Repairs &#8211; MD&amp;A Turbines\" \/>\n<meta property=\"og:description\" content=\"Steam turbine experts at MD&amp;A have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae Frame G2 unit.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/\" \/>\n<meta property=\"og:site_name\" content=\"MDA Turbines\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/mdaturbines\" \/>\n<meta property=\"article:published_time\" content=\"2022-05-04T19:31:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2400\" \/>\n\t<meta property=\"og:image:height\" content=\"1350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Caitlin Borger\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Caitlin Borger\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/\"},\"author\":{\"name\":\"Caitlin Borger\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/person\\\/fdbd01ed3b81195a72d31a7c9d59d29e\"},\"headline\":\"Spare LPB Rotor and Diaphragm Repairs\",\"datePublished\":\"2022-05-04T19:31:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/\"},\"wordCount\":974,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/DJI_0044-scaled.jpg\",\"keywords\":[\"steam turbine\",\"Steam Turbine Parts\",\"Steam Turbine Repairs\"],\"articleSection\":[\"Steam Turbine\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/\",\"name\":\"Spare LPB Rotor and Diaphragm Repairs &#8211; MD&A Turbines\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/DJI_0044-scaled.jpg\",\"datePublished\":\"2022-05-04T19:31:00+00:00\",\"description\":\"Steam turbine experts at MD&A have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae Frame G2 unit.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/DJI_0044-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/DJI_0044-scaled.jpg\",\"width\":2400,\"height\":1350,\"caption\":\"DCIM100MEDIADJI_0044.JPG\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/spare-lpb-rotor-and-diaphragm-repairs\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.mdaturbines.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Spare LPB Rotor and Diaphragm Repairs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"name\":\"MD&A Turbines\",\"description\":\"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\"},\"alternateName\":\"Mechanical Dynamics & Analysis\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.mdaturbines.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\",\"name\":\"Mechanical Dynamics & Analysis\",\"alternateName\":\"MD&A Turbines\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"width\":1179,\"height\":258,\"caption\":\"Mechanical Dynamics & Analysis\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/mdaturbines\",\"https:\\\/\\\/x.com\\\/mdaturbines\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/person\\\/fdbd01ed3b81195a72d31a7c9d59d29e\",\"name\":\"Caitlin Borger\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g\",\"caption\":\"Caitlin Borger\"},\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/author\\\/caitlin-borger\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Spare LPB Rotor and Diaphragm Repairs &#8211; MD&A Turbines","description":"Steam turbine experts at MD&A have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae Frame G2 unit.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/","og_locale":"en_US","og_type":"article","og_title":"Spare LPB Rotor and Diaphragm Repairs &#8211; MD&A Turbines","og_description":"Steam turbine experts at MD&A have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae Frame G2 unit.","og_url":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/","og_site_name":"MDA Turbines","article_publisher":"http:\/\/www.facebook.com\/mdaturbines","article_published_time":"2022-05-04T19:31:00+00:00","og_image":[{"width":2400,"height":1350,"url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-scaled.jpg","type":"image\/jpeg"}],"author":"Caitlin Borger","twitter_misc":{"Written by":"Caitlin Borger","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#article","isPartOf":{"@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/"},"author":{"name":"Caitlin Borger","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/person\/fdbd01ed3b81195a72d31a7c9d59d29e"},"headline":"Spare LPB Rotor and Diaphragm Repairs","datePublished":"2022-05-04T19:31:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/"},"wordCount":974,"commentCount":0,"publisher":{"@id":"https:\/\/www.mdaturbines.com\/#organization"},"image":{"@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-scaled.jpg","keywords":["steam turbine","Steam Turbine Parts","Steam Turbine Repairs"],"articleSection":["Steam Turbine"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/","url":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/","name":"Spare LPB Rotor and Diaphragm Repairs &#8211; MD&A Turbines","isPartOf":{"@id":"https:\/\/www.mdaturbines.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#primaryimage"},"image":{"@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-scaled.jpg","datePublished":"2022-05-04T19:31:00+00:00","description":"Steam turbine experts at MD&A have completed LPB rotor and diaphragm repairs of a spare 410 MW GE\u00ae Frame G2 unit.","breadcrumb":{"@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#primaryimage","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-scaled.jpg","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2022\/03\/DJI_0044-scaled.jpg","width":2400,"height":1350,"caption":"DCIM100MEDIADJI_0044.JPG"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mdaturbines.com\/resources\/spare-lpb-rotor-and-diaphragm-repairs\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mdaturbines.com\/"},{"@type":"ListItem","position":2,"name":"Spare LPB Rotor and Diaphragm Repairs"}]},{"@type":"WebSite","@id":"https:\/\/www.mdaturbines.com\/#website","url":"https:\/\/www.mdaturbines.com\/","name":"MD&A Turbines","description":"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..","publisher":{"@id":"https:\/\/www.mdaturbines.com\/#organization"},"alternateName":"Mechanical Dynamics & Analysis","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mdaturbines.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mdaturbines.com\/#organization","name":"Mechanical Dynamics & Analysis","alternateName":"MD&A Turbines","url":"https:\/\/www.mdaturbines.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","width":1179,"height":258,"caption":"Mechanical Dynamics & Analysis"},"image":{"@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/mdaturbines","https:\/\/x.com\/mdaturbines"]},{"@type":"Person","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/person\/fdbd01ed3b81195a72d31a7c9d59d29e","name":"Caitlin Borger","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/faa1bbe36738add63e725f8191397d3717e8a6996cb3e1307ba69d4d9114030f?s=96&d=mm&r=g","caption":"Caitlin Borger"},"url":"https:\/\/www.mdaturbines.com\/resources\/author\/caitlin-borger\/"}]}},"_links":{"self":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/70258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/comments?post=70258"}],"version-history":[{"count":5,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/70258\/revisions"}],"predecessor-version":[{"id":70692,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/70258\/revisions\/70692"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media\/70259"}],"wp:attachment":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media?parent=70258"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/categories?post=70258"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/tags?post=70258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}