{"id":66177,"date":"2020-01-24T13:42:25","date_gmt":"2020-01-24T18:42:25","guid":{"rendered":"https:\/\/www.mdaturbines.com\/?page_id=66177"},"modified":"2024-12-18T09:42:56","modified_gmt":"2024-12-18T14:42:56","slug":"9f-gas-turbine-lifetime-extension","status":"publish","type":"page","link":"https:\/\/www.mdaturbines.com\/9f-gas-turbine-lifetime-extension\/","title":{"rendered":"GE 9F Gas Turbine Lifetime Extension Clinic"},"content":{"rendered":"<p>Mechanical Dynamics &amp; Analysis (MD&amp;A) can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no longer suitable to operate. Significant savings can be realized by opting for lower-cost repaired spares instead of new parts.<\/p>\n<p>Elevated temperatures take a big toll on gas turbine components. Repair enhancements can extend a part\u2019s life by slowing its degradation and extending its usable service life.<\/p>\n<p>Formerly PW Powers Systems\u2019 IGT division, the MD&amp;A San Antonio Texas Service Center team have years of experience evaluating the life-limiting factors for gas turbine vanes and blades. Such factors include cracks, corrosion, wall thickness, and material condition. \u00a0Most crack limiting locations are found at the platform or shroud transition. Smaller percentages occur at the blade tip, the blade airfoil, or the root. Vane limiting factors are usually related to the wall thickness and material condition.<\/p>\n<p>Platform degradation can be reduced in many ways: by operating in base load only ( although dispatch conditions may prevent that from being a practical solution), by pursuing a robust platform weld repair program, by improving the integrity of the platform coating, and by making platform improvements.<\/p>\n<p>Thermal mechanical fatigue cracks will eventually lead to platform failure. Design modifications often are required, incorporating a robust repair procedure. The life cycle enhancement process used by our experts exceeds OEM platform properties.<\/p>\n<p>Our experts at the San Antonio Service Center combine years of experience with state-of-the-art equipment to deliver exactly the right solutions to your specific set of parts!<\/p>\n<h3>9FA 3rd Stage Blade Extended to 120,000 FFH<\/h3>\n<p>Three 9FA 3<sup>rd<\/sup> stage blades were received by our San Antonio facility where they underwent detailed inspections, including microstructural assessment and high-temperature testing.<\/p>\n<p>Observations indicated galling in root serrations and seal pin surfaces, as well as the presence of two distinct casting houses to produce the row of buckets.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-64011 size-medium\" title=\"gas turbine parts life extension\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/4-e1534252980655-226x300.png\" sizes=\"(max-width: 226px) 100vw, 226px\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/4-e1534252980655-226x300.png 226w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/4-e1534252980655-121x160.png 121w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/4-e1534252980655-68x90.png 68w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/4-e1534252980655.png 483w\" alt=\"gas turbine parts life extension\" width=\"226\" height=\"300\" \/><\/p>\n<p>Scope of work included a visual inspection, dimensional measurements, and an x-ray inspection. Also included were a microstructural assessment, high-temperature mechanical properties testing, assessment of material condition at multiple locations, heat treatment of specimens to demonstrate the effects of repairs, and high-temperature mechanical property testing performed post-heat treatment.<\/p>\n<p>Inspections showed that the manufacturer\u2019s heat treatment had not achieved full solutioning. All blades also displayed a two-phase gamma prime structure within each grain, indicating that the previous repair heat treatments were not optimized to achieve a good structure. In addition, all three blades had surface oxidation and depletion. Even so, the components all were deemed repairable.<\/p>\n<div id=\"attachment_64013\" class=\"wp-caption aligncenter\">\n<figure id=\"attachment_64013\" aria-describedby=\"caption-attachment-64013\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-medium wp-image-64013\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/5-300x142.png\" alt=\"9FA Surface Oxidation on Lead Edge, Gas Turbine Parts Lifetime Extension\" width=\"300\" height=\"142\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/5-300x142.png 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/5-90x43.png 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/5.png 515w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-64013\" class=\"wp-caption-text\">Surface Oxidation on Lead Edge<\/figcaption><\/figure>\n<\/div>\n<p>Additional repair work included grit blasting and polishing the gas path surfaces to remove an oxide layer, a complete X-ray inspection, and HVOF coating and diffusion to reduce surface degradation.<\/p>\n<p>MD&amp;A\u2019s Repair heat treatment was applied to several samples from the test blades, then evaluated to determine the material\u2019s response to these heat treatments. The material responded well to the heat treatments on all three blades. The gamma prime transformed to a more cuboidal morphology, which provides for improved component creep life.<\/p>\n<figure id=\"attachment_64014\" aria-describedby=\"caption-attachment-64014\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-medium wp-image-64014\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/6-300x208.png\" alt=\"Microstructure, Gas Turbine Parts Lifetime Extension\" width=\"300\" height=\"208\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/6-300x208.png 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/6-230x160.png 230w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/6-90x63.png 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/08\/6.png 527w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-64014\" class=\"wp-caption-text\">Microstructure<\/figcaption><\/figure>\n<p>These third-stage blades were evaluated and subsequently determined to be candidates for a Lifetime Extension (LTE) repair. The 9FA 3rd stage blades\u2019 lives were extended to 120K FFH.<\/p>\n<p>MD&amp;A\u2019s available Gas Turbine services range from full turnkey major inspections to rotor unstacking, gas turbine alignment, and control services. MD&amp;A is a global full-service OEM alternative for services, parts, and repairs.<\/p>\n<p>Call our MD&amp;A San Antonio Service Center, or our Gas Turbine Parts Service Facility today at +1 (210) 256-5000.<\/p>\n<p>Also, be sure to sign up for our <a href=\"https:\/\/www.mdaturbines.com\/ec-news-subscribe\/\">MD&amp;A Insight e-newsletter<\/a> delivered quarterly. Get our turbine-generator expert\u2019s case studies and tips! Fill in the sign-up form and SUBSCRIBE!<\/p>\n<form action=\"https:\/\/r.inbox.guru\/lc.aspx\" method=\"POST\">\n<hr \/>\n<\/form>\n<p><em>Proprietary Notice: WARNING \u2013 This document is the property of MD&amp;A.\u00a0 You may not possess, use, copy or distribute this document or any information in it for any purpose, including without limitation to design, manufacture or repair parts, or obtain FAA or other government approval to do so, without MD&amp;A express written permission. Neither receipt nor possession of this document alone, from any source, constitutes such permission. Possession, use, copying or disclosure by anyone without MD&amp;A express written permission is not authorized and may result in criminal and\/or civil liability. EAR commercial\/Civil or Dual- Use Notice: WARNING \u2014 This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export, re-export, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by MD&amp;A, is prohibited without prior written approval from MD&amp;A and authorization under applicable export control laws. EAR Export Classification: EAR 99<\/em><\/p>\n<p><em>\u00a9 2021 Mechanical Dynamics &amp; Analysis LLC. All Rights Reserved<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mechanical Dynamics &amp; Analysis (MD&amp;A) can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no&#8230;<\/p>\n","protected":false},"author":2,"featured_media":74496,"parent":0,"menu_order":22,"comment_status":"open","ping_status":"open","template":"","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"class_list":["post-66177","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Gas Turbine Lifetime Extension | MD&amp;A Turbines<\/title>\n<meta name=\"description\" content=\"MD&amp;A\u2019s San Antonio Service Center can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no longer suitable to operate.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Gas Turbine Lifetime Extension | MD&amp;A Turbines\" \/>\n<meta property=\"og:description\" content=\"MD&amp;A\u2019s San Antonio Service Center can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no longer suitable to operate.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/\" \/>\n<meta property=\"og:site_name\" content=\"MDA Turbines\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/mdaturbines\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-18T14:42:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/12\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/9f-gas-turbine-lifetime-extension\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/services\\\/steam-turbine\\\/remaining-life-finite-element-analysis\\\/\",\"name\":\"Gas Turbine Lifetime Extension | MD&A Turbines\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/services\\\/steam-turbine\\\/remaining-life-finite-element-analysis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/services\\\/steam-turbine\\\/remaining-life-finite-element-analysis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg\",\"datePublished\":\"2020-01-24T18:42:25+00:00\",\"dateModified\":\"2024-12-18T14:42:56+00:00\",\"description\":\"MD&A\u2019s San Antonio Service Center can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no longer suitable to operate.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/services\\\/steam-turbine\\\/remaining-life-finite-element-analysis\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.mdaturbines.com\\\/services\\\/steam-turbine\\\/remaining-life-finite-element-analysis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/services\\\/steam-turbine\\\/remaining-life-finite-element-analysis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg\",\"width\":1600,\"height\":450},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/services\\\/steam-turbine\\\/remaining-life-finite-element-analysis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.mdaturbines.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"GE 9F Gas Turbine Lifetime Extension Clinic\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"name\":\"MD&A Turbines\",\"description\":\"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\"},\"alternateName\":\"Mechanical Dynamics & Analysis\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.mdaturbines.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\",\"name\":\"Mechanical Dynamics & Analysis\",\"alternateName\":\"MD&A Turbines\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"width\":1179,\"height\":258,\"caption\":\"Mechanical Dynamics & Analysis\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/mdaturbines\",\"https:\\\/\\\/x.com\\\/mdaturbines\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Gas Turbine Lifetime Extension | MD&A Turbines","description":"MD&A\u2019s San Antonio Service Center can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no longer suitable to operate.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/","og_locale":"en_US","og_type":"article","og_title":"Gas Turbine Lifetime Extension | MD&A Turbines","og_description":"MD&A\u2019s San Antonio Service Center can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no longer suitable to operate.","og_url":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/","og_site_name":"MDA Turbines","article_publisher":"http:\/\/www.facebook.com\/mdaturbines","article_modified_time":"2024-12-18T14:42:56+00:00","og_image":[{"width":1600,"height":450,"url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/12\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg","type":"image\/jpeg"}],"twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mdaturbines.com\/9f-gas-turbine-lifetime-extension\/","url":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/","name":"Gas Turbine Lifetime Extension | MD&A Turbines","isPartOf":{"@id":"https:\/\/www.mdaturbines.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/#primaryimage"},"image":{"@id":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/12\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg","datePublished":"2020-01-24T18:42:25+00:00","dateModified":"2024-12-18T14:42:56+00:00","description":"MD&A\u2019s San Antonio Service Center can extend the service life of gas turbine components whose OEM service limit has passed or whose configuration is no longer suitable to operate.","breadcrumb":{"@id":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/#primaryimage","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/12\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2024\/12\/9f-gas-turbine-lifetime-extension_-_ge-9fa-turbine.jpg","width":1600,"height":450},{"@type":"BreadcrumbList","@id":"https:\/\/www.mdaturbines.com\/services\/steam-turbine\/remaining-life-finite-element-analysis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mdaturbines.com\/"},{"@type":"ListItem","position":2,"name":"GE 9F Gas Turbine Lifetime Extension Clinic"}]},{"@type":"WebSite","@id":"https:\/\/www.mdaturbines.com\/#website","url":"https:\/\/www.mdaturbines.com\/","name":"MD&A Turbines","description":"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..","publisher":{"@id":"https:\/\/www.mdaturbines.com\/#organization"},"alternateName":"Mechanical Dynamics & Analysis","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mdaturbines.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mdaturbines.com\/#organization","name":"Mechanical Dynamics & Analysis","alternateName":"MD&A Turbines","url":"https:\/\/www.mdaturbines.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","width":1179,"height":258,"caption":"Mechanical Dynamics & Analysis"},"image":{"@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/mdaturbines","https:\/\/x.com\/mdaturbines"]}]}},"_links":{"self":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/pages\/66177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/comments?post=66177"}],"version-history":[{"count":6,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/pages\/66177\/revisions"}],"predecessor-version":[{"id":71788,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/pages\/66177\/revisions\/71788"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media\/74496"}],"wp:attachment":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media?parent=66177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}