{"id":63784,"date":"2018-06-18T10:29:01","date_gmt":"2018-06-18T14:29:01","guid":{"rendered":"https:\/\/www.mdaturbines.com\/?p=63784"},"modified":"2020-01-30T14:13:29","modified_gmt":"2020-01-30T19:13:29","slug":"generator-field-support-platform","status":"publish","type":"post","link":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/","title":{"rendered":"Generator Field Support Platform"},"content":{"rendered":"<p>Mechanical Dynamics &amp; Analysis (MD&amp;A) experts have constructed a <a href=\"https:\/\/www.mdaturbines.com\/repairs\/generator\/\">generator field support<\/a> platform to allow for removal of the field when performing a 7FH2 Generator Major Inspection.<\/p>\n<p><a href=\"https:\/\/www.mdaturbines.com\/services\/generator\/generator-testing-inspections\/\">Rotor field inspections<\/a> can either be performed on-site or in a shop environment.\u00a0 Repairs generally require the rotor field to be transported <a href=\"https:\/\/www.mdaturbines.com\/repairs\/generator\/field-services\/\">to a qualified repair facility.\u00a0<\/a><\/p>\n<p>MD&amp;A has developed a field pulling &amp; support system to address the unique challenges associated with the 7FA\/7FH2 configuration: 1) the shaft centerline height is 13 feet above machine baseline (grade), and 2) the gas turbine inlet ducting and filter house limit crane access.<\/p>\n<p>The MD&amp;A system consists of a modular work platform using adjustable rotor field trolley carts to efficiently and safely extract the field from the stator core, providing a stable work platform for on-site inspections and sufficient length to enable crane access to lift the field for off-site repair transportation.<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\" border=\"0\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\"><img decoding=\"async\" class=\"aligncenter wp-image-63787 size-medium\" title=\"Generator Field Support Platform\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-2-300x200.jpg\" alt=\"Generator Field Support Platform\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-2-300x200.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-2-240x160.jpg 240w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-2-90x60.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-2.jpg 660w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<td style=\"width: 50%;\"><img decoding=\"async\" class=\"aligncenter wp-image-63788 size-medium\" title=\"Generator Field Support Platform\" src=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1-300x200.jpg\" alt=\"Generator Field Support Platform\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1-300x200.jpg 300w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1-240x160.jpg 240w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1-90x60.jpg 90w, https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1.jpg 660w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Key features of the system include:<\/p>\n<ul class=\"normal\">\n<li>Modular design work platform for expedited setup\/teardown and efficient transportation on standard trailers<\/li>\n<li>Overall platform length and height can be adjusted based on site and workscope requirements<\/li>\n<li>Tongue and groove work platform connections and integrated trolley cart rail system provide seamless transitions between platforms<\/li>\n<li>Wide walkway wings on left &amp; right sides enable worker &amp; equipment access<\/li>\n<li>Modular safety rail system allows flexible scaffold stair access based on site arrangement<\/li>\n<li>Adjustable trolley carts use low-friction, self-guided rollers for safe and fast positioning of the field on the platform<\/li>\n<li>The system is very stable and is rated for continuous use with steady wind speeds up to 30 mph (with minimum 3x factor of safety)<\/li>\n<\/ul>\n<p>MD&amp;A offers a complete suite of <a href=\"https:\/\/www.mdaturbines.com\/parts\/gas-turbine\/\">parts<\/a>, <a href=\"https:\/\/www.mdaturbines.com\/repairs\/gas-turbine\/\">repairs<\/a>, and <a href=\"https:\/\/www.mdaturbines.com\/services\/gas-turbine\/\">services<\/a> solutions for gas turbine fleets. We focus on delivering consistent quality and value with fast response, superior communications, and innovative solutions.<\/p>\n<p><strong>Call our MD&amp;A Gas Turbine Services today at\u00a0+1 (518) 399-3616 or use our <\/strong><a href=\"https:\/\/www.mdaturbines.com\/contact\/\">Contact form<\/a><strong>.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mechanical Dynamics &amp; Analysis (MD&amp;A) experts have constructed a generator field support platform to allow for removal of the field when performing a 7FH2 Generator&#8230;<\/p>\n","protected":false},"author":2,"featured_media":63788,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[210],"tags":[67,78,79,70],"class_list":["post-63784","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-generator","tag-7fa","tag-7fh2","tag-generator-inspection","tag-generator-repair"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Generator Field Support Platform &#8211; MDA Turbines<\/title>\n<meta name=\"description\" content=\"MD&amp;A experts have constructed a generator field support platform to allow for removal of the field when performing a 7FH2 Generator Major Inspection.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Generator Field Support Platform &#8211; MDA Turbines\" \/>\n<meta property=\"og:description\" content=\"MD&amp;A experts have constructed a generator field support platform to allow for removal of the field when performing a 7FH2 Generator Major Inspection.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/\" \/>\n<meta property=\"og:site_name\" content=\"MDA Turbines\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/mdaturbines\" \/>\n<meta property=\"article:published_time\" content=\"2018-06-18T14:29:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-01-30T19:13:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"660\" \/>\n\t<meta property=\"og:image:height\" content=\"440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kelly Plunkett\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kelly Plunkett\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/\"},\"author\":{\"name\":\"Kelly Plunkett\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/person\\\/ee0e84e14abc852781ad53a495c0533c\"},\"headline\":\"Generator Field Support Platform\",\"datePublished\":\"2018-06-18T14:29:01+00:00\",\"dateModified\":\"2020-01-30T19:13:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/\"},\"wordCount\":323,\"publisher\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Generator-Field-Support-Platform-1.jpg\",\"keywords\":[\"7FA\",\"7FH2\",\"generator inspection\",\"generator repair\"],\"articleSection\":[\"Generator\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/\",\"name\":\"Generator Field Support Platform &#8211; MDA Turbines\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Generator-Field-Support-Platform-1.jpg\",\"datePublished\":\"2018-06-18T14:29:01+00:00\",\"dateModified\":\"2020-01-30T19:13:29+00:00\",\"description\":\"MD&A experts have constructed a generator field support platform to allow for removal of the field when performing a 7FH2 Generator Major Inspection.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Generator-Field-Support-Platform-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Generator-Field-Support-Platform-1.jpg\",\"width\":660,\"height\":440,\"caption\":\"Generator Field Support Platform\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/generator-field-support-platform\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.mdaturbines.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Generator Field Support Platform\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#website\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"name\":\"MD&A Turbines\",\"description\":\"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\"},\"alternateName\":\"Mechanical Dynamics & Analysis\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.mdaturbines.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#organization\",\"name\":\"Mechanical Dynamics & Analysis\",\"alternateName\":\"MD&A Turbines\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"contentUrl\":\"https:\\\/\\\/www.mdaturbines.com\\\/wp-content\\\/uploads\\\/2019\\\/01\\\/MDA_logo.gif\",\"width\":1179,\"height\":258,\"caption\":\"Mechanical Dynamics & Analysis\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/mdaturbines\",\"https:\\\/\\\/x.com\\\/mdaturbines\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.mdaturbines.com\\\/#\\\/schema\\\/person\\\/ee0e84e14abc852781ad53a495c0533c\",\"name\":\"Kelly Plunkett\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d3226d1c3a5895b8e94c98ac7ba906834a28fd94afa044b35e616d164290cffb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d3226d1c3a5895b8e94c98ac7ba906834a28fd94afa044b35e616d164290cffb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d3226d1c3a5895b8e94c98ac7ba906834a28fd94afa044b35e616d164290cffb?s=96&d=mm&r=g\",\"caption\":\"Kelly Plunkett\"},\"sameAs\":[\"https:\\\/\\\/www.mdaturbines.com\"],\"url\":\"https:\\\/\\\/www.mdaturbines.com\\\/resources\\\/author\\\/kelly-plunkett\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Generator Field Support Platform &#8211; MDA Turbines","description":"MD&A experts have constructed a generator field support platform to allow for removal of the field when performing a 7FH2 Generator Major Inspection.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/","og_locale":"en_US","og_type":"article","og_title":"Generator Field Support Platform &#8211; MDA Turbines","og_description":"MD&A experts have constructed a generator field support platform to allow for removal of the field when performing a 7FH2 Generator Major Inspection.","og_url":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/","og_site_name":"MDA Turbines","article_publisher":"http:\/\/www.facebook.com\/mdaturbines","article_published_time":"2018-06-18T14:29:01+00:00","article_modified_time":"2020-01-30T19:13:29+00:00","og_image":[{"width":660,"height":440,"url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1.jpg","type":"image\/jpeg"}],"author":"Kelly Plunkett","twitter_misc":{"Written by":"Kelly Plunkett","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/#article","isPartOf":{"@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/"},"author":{"name":"Kelly Plunkett","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/person\/ee0e84e14abc852781ad53a495c0533c"},"headline":"Generator Field Support Platform","datePublished":"2018-06-18T14:29:01+00:00","dateModified":"2020-01-30T19:13:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/"},"wordCount":323,"publisher":{"@id":"https:\/\/www.mdaturbines.com\/#organization"},"image":{"@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1.jpg","keywords":["7FA","7FH2","generator inspection","generator repair"],"articleSection":["Generator"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/","url":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/","name":"Generator Field Support Platform &#8211; MDA Turbines","isPartOf":{"@id":"https:\/\/www.mdaturbines.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/#primaryimage"},"image":{"@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1.jpg","datePublished":"2018-06-18T14:29:01+00:00","dateModified":"2020-01-30T19:13:29+00:00","description":"MD&A experts have constructed a generator field support platform to allow for removal of the field when performing a 7FH2 Generator Major Inspection.","breadcrumb":{"@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/#primaryimage","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1.jpg","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2018\/06\/Generator-Field-Support-Platform-1.jpg","width":660,"height":440,"caption":"Generator Field Support Platform"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mdaturbines.com\/resources\/generator-field-support-platform\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mdaturbines.com\/"},{"@type":"ListItem","position":2,"name":"Generator Field Support Platform"}]},{"@type":"WebSite","@id":"https:\/\/www.mdaturbines.com\/#website","url":"https:\/\/www.mdaturbines.com\/","name":"MD&A Turbines","description":"MDA Turbines is one of the largest turbine-generator repair and turbine engineering organizations in the US..","publisher":{"@id":"https:\/\/www.mdaturbines.com\/#organization"},"alternateName":"Mechanical Dynamics & Analysis","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mdaturbines.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mdaturbines.com\/#organization","name":"Mechanical Dynamics & Analysis","alternateName":"MD&A Turbines","url":"https:\/\/www.mdaturbines.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","contentUrl":"https:\/\/www.mdaturbines.com\/wp-content\/uploads\/2019\/01\/MDA_logo.gif","width":1179,"height":258,"caption":"Mechanical Dynamics & Analysis"},"image":{"@id":"https:\/\/www.mdaturbines.com\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/mdaturbines","https:\/\/x.com\/mdaturbines"]},{"@type":"Person","@id":"https:\/\/www.mdaturbines.com\/#\/schema\/person\/ee0e84e14abc852781ad53a495c0533c","name":"Kelly Plunkett","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d3226d1c3a5895b8e94c98ac7ba906834a28fd94afa044b35e616d164290cffb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d3226d1c3a5895b8e94c98ac7ba906834a28fd94afa044b35e616d164290cffb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d3226d1c3a5895b8e94c98ac7ba906834a28fd94afa044b35e616d164290cffb?s=96&d=mm&r=g","caption":"Kelly Plunkett"},"sameAs":["https:\/\/www.mdaturbines.com"],"url":"https:\/\/www.mdaturbines.com\/resources\/author\/kelly-plunkett\/"}]}},"_links":{"self":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/63784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/comments?post=63784"}],"version-history":[{"count":6,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/63784\/revisions"}],"predecessor-version":[{"id":77902,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/posts\/63784\/revisions\/77902"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media\/63788"}],"wp:attachment":[{"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/media?parent=63784"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/categories?post=63784"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mdaturbines.com\/wp-json\/wp\/v2\/tags?post=63784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}